Background
A leading convertor in western India has a state of the art speciality coating line where they process polyester (PET)
films 10 - 350 μm thick
Challenge
The convertor coats the films with a uniform thickness of a special solvent based material. The coated film is then
passed through a drying chamber where thermic fluid is used for heating. Waste hot air that is used for drying is
exhausted from dryer at 155°C.
Solution
AxisValence approached the convertor and suggested they evaluate the feasibility of energy recovery devices to
reduce heating costs. The AxisValence team observed that 80% of the energy of hot air was being wasted.
To extract a good part of the heat, AxisValence proposed the Lamiflow heat recovery system which is a cross flow,
air-to-air heat exchanger. It comprises multiple, thin, slightly separated plates that provide large surface area for
effective heat transfer with low pressure drop.
The Lamiflow heat recovery system is installed in a way that the two air streams - ambient air and hot air (exiting
dryer) - cross each other without mixing. The heat extracted from the exhaust air is effectively used to preheat fresh
air before it enters the heater. Thermal energy costs are thus reduced by decreasing load on the heater.

Result
Considering 16 hours operation of the coating machine each day, for 300 working days in a year and assuming that
savings happen only 60% of the time, this solution pays for itself in about 7 months.
The customer is very happy with the cost savings and is exploring other areas for waste heat recovery through
AxisValence products.
AxisValence has extensive experience and expertise in various applications across industries, which we leverage to
provide a suitable solution for your application.